Maintenance Commands
555-233-143
7-190
Issue 1 May 2002
list measurements ds1-log 2a19
Switch Name: Date: 1:26 pm THU APR 16, 2002
DS-1 Link Performance Measurements Detailed Log Report
Counted Since: 1:20 pm THU APR 16, 2002
ERRORED BURSTY SEVERELY FAILED VALID
DATE TIME SECOND ERR SECS ERR SECS SECONDS INTERVAL
4/16 13:05 0 0 0 0 y
4/16 13:20 0 0 0 0 y
Command successfully completed
list measurements ds1-facility log 2e01a
Switch Name: Date: 1:26 pm THU APR 16, 2002
DS1C Link Performance Measurements Detailed Log Report
Counted Since: 10:50 am THU APR 16, 2002
ERRORED BURSTY SEVERELY FAILED VALID
DATE TIME SECOND ERR SECS ERR SECS SECONDS INTERVAL
4/16 11:05 0 0 0 0 y
4/16 11:20 0 0 0 0 y
4/16 11:35 0 0 0 0 y
4/16 11:50 0 0 0 0 y
4/16 12:05 0 0 0 0 y
4/16 12:20 0 0 0 0 y
4/16 12:35 0 0 0 0 y
4/16 12:50 0 0 0 0 y
4/16 13:05 0 0 0 0 y
4/16 13:20 0 0 0 0 y
Command successfully completed