FIBER-LK (Fiber Link)
Issue 1 May 2002
8-867
555-233-143
243
FAIL
The SNI circuit pack (Endpoint 2 of the fiber link) has a loss-of-signal condition,
but no fiber out-of-frame condition. Also, a lightwave transceiver is connected
to the SNI circuit pack.
1. Check that the connected circuit pack is physically installed. The
connected circuit pack is the other endpoint of the fiber-link if no DS1
CONV complex is administered (check via list fiber-link). Otherwise, if a
DS1 CONV complex is administered, the connected circuit pack is the DS1
CONV circuit pack connected to the SNI circuit pack.
2. Perform the
‘‘Fault Isolation for Fiber Links’’ on page 4-19
in Chapter 5.
3. Replace this SNI circuit pack.
4. Replace the connected circuit pack.
244
FAIL
The SNI circuit pack (Endpoint 2 of the fiber link) has a loss-of-signal condition,
but no fiber out-of-frame condition. Also, no lightwave transceiver is connected
to the SNI circuit pack.
1. Check that the connected circuit pack is physically installed. The
connected circuit pack is the other endpoint of the fiber link if no DS1
CONV complex is administered (check via list fiber-link). Otherwise, if a
DS1 CONV complex is administered, the connected circuit pack is the DS1
CONV circuit pack connected to the SNI circuit pack.
2. Perform the
‘‘Fault Isolation for Fiber Links’’ on page 4-19
in Chapter 5.
3. Replace this SNI circuit pack.
4. Replace the connected circuit pack.
245
FAIL
The SNI circuit pack (Endpoint 2 of the fiber link) has a fiber out-of-frame
condition and a loss-of-signal condition. Also, a lightwave transceiver is
connected to the SNI circuit pack.
1. Check that the connected circuit pack is physically installed. The
connected circuit pack is the other endpoint of the fiber link if no DS1
CONV complex is administered (check via list fiber-link). Otherwise, if a
DS1 CONV complex is administered, the connected circuit pack is the DS1
CONV circuit pack connected to the SNI circuit pack.
2. Perform the
‘‘Fault Isolation for Fiber Links’’ on page 4-19
in Chapter 5.
3. Replace this SNI circuit pack.
4. Replace the connected circuit pack.
Table 8-331.
Test #989 SNI Fiber Out of Frame Query —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...