Maintenance Commands
555-233-143
7-274
Issue 1 May 2002
set options
This command allows the user to administer whether certain alarms are reported
to INADS or whether they are downgraded to a minor alarm, warning alarm, or no
alarm.
Synopsis
set options
Permissions
The following default logins may execute this command:
inads, init.
Examples
set options
Description
This special command enables the technician (that is, remote user with INADS
permission) to select which types of maintenance categories report alarms
automatically and which types require the customer to call in. Judicious use of
this command can reduce the number of ineffective alarms to the TSC. For the
set options command to be effective, the default settings specified in this section
should always be used. These settings are not intended to be changed on a
per-system basis. Special circumstances (for example, special studies) may
require temporary changes under the guidance of Tiers 3 and 4.
NOTE:
Alarms cannot be upgraded.
Defaults
Initially, the alarm reporting options for On-board Trunk Alarms (Alarm Group 1),
both major and minor, are set to “yes” (y); all others are set to “warning” (w).
Every trunk group is associated with alarm severity group 1 by default.
Parameters
None.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...