ASAI-EPT
Issue 1 May 2002
8-147
555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol.
Timers associated with certain layer-3 messages have expired before a
required response was received. In the following table, the aux data
column indicates which timer has just expired. For more information, refer
to the Avaya ISDN-BRI Specification.
Table 8-56.
ASAI-EPT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
ASAI-EPT
On/ Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test ASAI-ADJ
2 (a)
2-102
None
257 (b)
Any
BRI Layer 3
query
MAJOR
WARNING
2
2.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
OFF
test station ext r 2
test data-module ext r 2
351 (c)
0
none
WARNING
OFF
busyout and release
station
513 (d)
0
None
769 (e)
0
None
MAJOR
OFF
2561 (f)
0
None
2562-
2566 (g)
0
None
2567 (h)
0
None
2568 (i)
0
None
3329 (j)
Any
Signaling Link
status (#626)
MAJOR
WARNING
†
OFF
3584-
3839 (k)
Any
None
3841 (l)
4095
Any
None
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...