UPS (Server UPS)
Issue 1 May 2002
8-1811
555-233-143
Trap #3, Event ID #10
upsAlarmShutdownPending
Alarm string = #1, ACT, UPS, A, 10, WRN, Miscellaneous trap, e.g.,
bad battery.
This UPS trap [Event #10] is a miscellaneous environmental alarm
sent from the UPS that supports server A. For example the battery
may be bad/low and a Shutdown is in progress.
Trap # 4, Event ID #11
upsAlarmShutdownPending
Alarm string = #1,ACT, UPS, A, 11, WRN, Miscellaneous trap, e.g.,
bad battery.
This UPS trap [Event #10] is a miscellaneous environmental alarm
sent from the UPS that supports server A. For example, the battery
may be bad/low and a Shutdown is in progress.
Trap #3, Event ID #12
1
upsAlarmShutdownImminent
Alarm string = #1,ACT, UPS, A, 12, MAJ, Miscellaneous trap, e.g.,
bad battery.
This UPS trap [Event #10] is a miscellaneous environmental alarm
sent from the UPS that supports server A. For example, the battery
may be bad/low and a Shutdown is in progress.
Trap (4), Event ID #13
1
upsAlarmShutdownImminent
Alarm string = #1,ACT,UPS,A,13,MAJ,Miscellaneous trap, e.g., bad
battery.
This UPS trap [Event #10] is a miscellaneous environmental alarm
sent from the UPS that supports server A. For example, the battery
may be bad/low and a Shutdown is in progress.
Trap (3), Event ID #14
1
upsAlarmDepletedBattery
Alarm string = #1,ACT,UPS,A,14,MAJ,Miscellaneous trap, e.g., bad
battery.
This UPS trap [Event #14] is a miscellaneous environmental alarm
sent from the UPS that supports server A. For example, the battery
may be bad/low and should be replaced.
Trap (4), Event ID #15
1
upsAlarmDepletedBattery
Alarm string = #1,ACT,UPS,A,15,MAJ,Miscellaneous trap, e.g., bad
battery
This UPS trap [Event #14] is a miscellaneous environmental alarm
sent from the UPS that supports server A. For example, the battery
may be bad/low and should be replaced.
Trap (3), Event ID #16
1
upsAlarmBatteryBad
Alarm string = #1,ACT,UPS,A,16,MIN,Miscellaneous trap, e.g., bad
battery
This UPS trap [Event #16] is a miscellaneous environmental alarm,
sent from the UPS that in this case supports server A. For
example, the battery may be bad and should be replaced.
Trap (4), Event ID #17
upsAlarmBatteryBad
Alarm string = #1,ACT,UPS,A,17,MIN,Miscellaneous trap, e.g., bad
battery
This UPS trap [Event #17] is a miscellaneous environmental alarm,
sent from the UPS that in this case supports server A. For
example, the battery may be bad and should be replaced.
Table 8-692.
Server’s SNMP Traps —
Continued
Enterprise Specific Trap and
Event Numbers
Definition of Traps
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...