![Avaya S8700 Series Maintenance Manual Download Page 2027](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022027.webp)
POWER
Issue 1 May 2002
8-1305
555-233-143
Note:
a. Check to see if the battery charger is connected. If the cabinet is powered
by a UPS, there is no battery backup, and this error can be ignored.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Battery and Battery Charger Query test (#5), you may also clear errors generated
from other tests in the testing sequence.
Notes:
a. See
for a description of this test.
b. See
‘‘CARR-POW (Carrier Power Supply)’’ on page 8-393
for a description of
this test.
c. See EMG-XFER (Emergency Transfer) for a description of this test.
d. See
‘‘CABINET (Cabinet Sensors)’’ on page 8-383
for a description of this
test.
e. See EXT-DEV (External Alarm) for a description of this test.
f. See
for a description of this test.
Table 8-523.
System Technician-Demanded Tests: POWER
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive, ND = Nondestructive
Battery and Battery Charger Query test (#5)
X
X
ND
AC Power Query test (#78) (a)
X
X
ND
Power Unit Query test (carrier E) (#127) (b)
X
X
ND
Power Unit Query test (carrier D) (#127) (b)
X
X
ND
Power Unit Query test (carrier A) (#127) (b)
X
X
ND
Power Unit Query test (carrier B) (#127) (b)
X
X
ND
Power Unit Query test (carrier C) (#127) (b)
X
X
ND
Emergency Transfer Query test (#124) (c)
X
X
ND
Cabinet Sensors Query test (#122) (d)
X
X
ND
External Alarm Lead Query test (#120) (e)
X
X
ND
Analog Ring Generator Initialization test (#117) (f)
X
X
ND
Analog Ring Generator Query test (#118) (f)
X
X
ND
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...