RANL-STA (Remote Analog Line (Station) Port
Issue 1 May 2002
8-1337
555-233-143
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The port’s battery feed chip is unable to supply sufficient power to the terminal
equipment. This could be a marginal test, and the terminal equipment may be
operating satisfactorily.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, determine whether the customer is experiencing
problems on this line. Replace the circuit pack only if the customer is
experiencing problems.
PASS
The port’s battery feed chip can provide power to the station equipment to
detect on-/off-hook, but may not be able to supply power for touch tones. If
touch tones are inoperative on this station, then replace the circuit pack
because this port is inoperative.
User-reported troubles on this port should be investigated by using other port
tests, by examining station wiring, or by examining the station.
Table 8-540.
Test #35 Battery Feed Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...