![Avaya S8700 Series Maintenance Manual Download Page 2578](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022578.webp)
Maintenance-Object Repair Procedures
555-233-143
8-1856
Issue 1 May 2002
VC Port Reset DSP Test (#1106)
This test is destructive.
This test resets the VC-DSPPT and the DSP associated with it. As part of the
reset procedure, the VC-DSPPT will execute a series of self-tests on the
hardware. If these self-tests fail, the test will fail; otherwise the test will pass.
Before executing the test, the VC-DSPPT must be busied out by executing the
busy port UUCSSpp command. After the completion of the test, the VC-DSPPT
must be released by executing the release port UUCSSpp command.
Table 8-711.
Test #1106 VC Port Reset DSP Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available, or the port may be
busy with a call.
1. Retry the command at 1-minute intervals up to 5 times.
1015
ABORT
The VC-DSPPT is not busied out.
1. Busyout the VC-DSPPT by executing the busy port UUCSSpp command,
and then retry the test.
2000
ABORT
Response to the test was not received from the VC-DSPPT within the
allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The reset of the VC-DSPPT was unsuccessful.
1. Replace circuit pack.
PASS
The VC-DSPPT was successfully reset.
1. Release the VC-DSPPT by executing the reset port UUCSSpp command.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...