status packet-interface
Issue 1 May 2002
7-365
555-233-143
status packet-interface
status packet-interface [cabinet #] [print]
The status packet-interface command displays the status of all packet-interface
circuit packs in the system along with link information. The service state is
displayed for both active and standby packet-interface circuit packs. Link status
information including total, active and failed links are displayed for active
packet-interface circuit packs only.
If there are no standby Packet Interface circuit packs, or if the standby is
inaccessible (due to handshake failure or incomplete memory refresh) the
standby packet-interface circuit packs will be in the uninstalled state.
When a packet-interface circuit pack is out-of-service or uninstalled, it is not used
to establish and maintain links. When the circuit pack returns to in-service status,
new links are again assigned to it.
This command currently provides status for up to five packet interfaces. The
command line takes a cabinet number as an argument and displays information
about all packet interfaces for the cabinet. If there are no IPSIs in the requested
cabinet, an error displays.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...