Error Log Entries and Test to Clear Values
Notes:
a. Error type 1 indicates the circuit pack has stopped functioning or has been
physically removed from the system. This error type does not apply to
ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD. The alarm is
logged approximately 11 minutes after removal of the circuit pack or failure
of the SAKI Sanity test (#53).
Check for the physical presence of the circuit pack in the slot indicated by
the alarm. If the circuit pack is absent, insert one of the proper type. If the
circuit pack is present and its red LED is lit, see
Log Entry or with Error Type 1’’ on page 6-5
.
b. This error indicates the circuit pack has been busied out. Release the
circuit pack via release board UUCSS.
Table 8-721.
Common Port Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test board UUCSS sh r 1
1 (a)
0
Circuit pack removed or
SAKI Sanity test (#53)
MINOR
ON
18 (b)
0
busyout board UUCSS
WARNING
OFF
release board UUCSS
23(c)
0
None
WARNING
OFF
36 (d)
4368
none
125 (e)
None
MINOR
ON
217 (f)
0
None
WARNING
ON
257
65535
Control Channel test
(#52)
MINOR
ON
test board UUCSS sh r
20
267 (f)
0
None
WARNING
ON
513 (h)
Any
None
MINOR
ON
test board UUCSS sh
769 (i)
4358
None
1025 (j)
4363
NPE Audit test (#50)
test board UUCSS l r 20
1281 (k)
Ringing Application test
(#51)
MINOR
ON
test board UUCSS r 2
1538 (l)
Any
None
WARNING
MINOR
ON
1793 (m)
Neon test (#220)
MINOR
ON
test board UUCSS r 2
3840 (n)
Any
None
3999 (o)
Any
None
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...