ABORT
The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1018
ABORT
The test has been disabled by administration. The default for the
Test
field
on the station form is y. Determine why this field has been set to “no” on this
station (this may be due to the ringing application Test #48, that can be
customer or terminal disturbing.
1. To enable the test for a particular station being tested, enter change
station extension and set the “Test?” field on the station from “n” to “y.”
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run test are not available. This could be due to a
failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
This test can fail due to either on- or off-board problems. Off-board problems
include EXP-PN and EXP-INTF faults, TDM-BUS faults, and faults associated
with the Tone Detectors/Tone Generators. Clear every off-board problem
before replacing the board. A TDM-BUS problem is usually the result of a
faulty board connected to the backplane, or bent pins on the backplane.
1. Resolve any EXP-PN or EXP-INTF errors.
2. Resolve any TDM-BUS errors.
3. Resolve any TONE-BD or TONE-PT errors.
4. Test the board when the faults from steps 1, 2, and 3 are cleared. Replace
the board only if the test fails.
PASS
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated by using other port tests, by examining station
wiring, or by examining the station.
Table 8-20.
Test #6 NPE Crosstalk Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...