Maintenance-Object Repair Procedures
555-233-143
8-1776
Issue 1 May 2002
DS1 Board Loop-back Test (#1209)
This test is destructive.
The DS1 BLB (Board Loopback) test causes a loop back at the DS1 board edge
and tests DS1 board internal circuitry.
The test is destructive and can only be initiated by a system technician demanded
test ds1-loop UUCSS ds1/csu-loopback-tests command.
Every trunk or port on the UDS1 Interface circuit pack must be busied out using
the system technician busyout board command before running the BLB test.
When the BLB test is initiated, maintenance software sends an appropriate
message to the UDS1 Interface circuit pack to start the test. The board sets up
the BLB loopback, transmits a test pattern, and verifies that the pattern is received
unaltered through the loopback. If the transmitted and received pattern is
different, the test fails.
When the test is complete, every trunk or port on the TN464GP/TN2464BPTN
UDS1 Interface circuit pack is restored to the in-service state after the release
board command is entered.
Table 8-682.
Test #1209 DS1 Board Loop-Back Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the test ds1-loop UUCSS ds1/csu-loopback-tests command at
1-minute intervals up to 5 times.
1005
ABORT
DS1 Board Loopback test cannot be executed in the current configuration. To
run this, the TN464F or later suffix UDS1 must be administered for 24-channel
operation. The “Bit Rate” field on the DS1 circuit pack administration form must
be set to “1.544” for 24-channel operation.
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put every trunk or port of
the UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...