Maintenance-Object Repair Procedures
555-233-143
8-1168
Issue 1 May 2002
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present, or some tone detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
4. If the test continues to abort, escalate the problem.
1004
ABORT
The port was seized by a valid ISDN-PRI test call. Use the list isdn-testcall
command to determine which call is using the port (from the M/T Port column).
Either wait for the test call to complete (as indicated in the
Start Time
and
Duration
fields of the above display), or abort the test call with the clear
isdn-testcall grp/mem command, where grp/mem is determined from the
B-channel
field of the above display.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the problem.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the test at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
7
FAIL
Conference test failed on the primary information channel. In most cases, the
user may not notice a disruption in service.
1. Run the circuit pack tests to check the Tone Generator circuit pack and the
Tone Detector circuit pack via the test board UUCSS command.
2. Resolve any problems that are detected on the Tone Generator circuit pack
or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly, and the test still fails, replace the Maintenance/Test circuit pack.
Table 8-478.
Test #13 Digital Port Loop-Around Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...