PMS-LINK (Property Management System Link)
Issue 1 May 2002
8-1275
555-233-143
m. The link was taken down by the switch because the threshold for
application protocol violations has been exceeded by the PMS. The
protocol never started and messages were received and/or messages
were received in a state in which they were not expected. (Refer to Error
Type 2817 for recommended strategy.)
n. Link was taken down by the switch because the threshold for link protocol
violations has been exceeded by the PMS. PMS is sending “garbage” to
the switch.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. For example,
by clearing error codes associated with the Link Tear Down test (#213), you may
also clear errors generated from other tests in the testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Link Tear Down test (#213)
X
D
Link Retry test (#215)
X
X
ND
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...