Maintenance Commands
555-233-143
7-402
Issue 1 May 2002
For an ip-medpro-ip hairpin call, the Audio Switch Port field shows a cabinet and
slot, but not a port, on a TN2302 Prowler board.
The following display shows a typical result when
status trunk 1 is entered for a
trunk group with two members.
The following display shows a typical result when status trunk 1 is entered for a
trunk group with two members.
status trunk 1/19
TRUNK STATUS
Trunk Group/Member: 01/19 Service State: in-service/active
Port: T00123 Maintenance Busy? no
Signaling Group ID: 1 CA-TSC state: not allowed
MM Conference ID: 8
MM Endpoint ID: 2
Connected Ports: S00004
Switch IP IP
Port Near-end IP Addr: Port Far-end IP Addr : Port
Q.931: 12B1217 xxx.xxx.xxx.xxx : nnnnn xxx.xxx.xxx.xxx : nnnnn
H.245: 12B1217 xxx.xxx.xxx.xxx : nnnnn xxx.xxx.xxx.xxx : nnnnn
G.711-MU Audio: T00123 xxx.xxx.xxx.xxx : nnnnn xxx.xxx.xxx.xxx
: nnnnn
H.245 Tunneled in Q.931? no
Audio Connection Type: ip direct
status trunk 1
TRUNK GROUP STATUS
Member Port Service State Mtce Busy Connected Ports
01/01 01A0101 in-service/idle no 01A0501 02B0607
01/02 04A0702 in-service/idle no 04C0604
status trunk 1
TRUNK GROUP STATUS
Member Port Service State Mtce Busy Connectd Ports
01/01 01A0101 in-service/idle no 01A0501 02B0607
01/02 04A0702 in-service/idle no 04C0604
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...