![Avaya S8700 Series Maintenance Manual Download Page 708](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102708.webp)
Maintenance Commands
555-233-143
7-452
Issue 1 May 2002
!
WARNING:
Since the clear long option clears every counter if the test passes, it is
possible for firmware counters to be cleared even though a problem exists.
In some cases customer service might degrade since calls may be routed
over defective equipment.
Output
The following example shows the output for the
test pkt port-network 1
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field Descriptions
Port
A port network number (1 – 44).
Maintenance
Name
The name of maintenance object being tested.
Alt. Name
Not applicable.
Test No
The test being executed.
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer to the
detailed list of the codes by test number for each MO.
test pkt port-network 1
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
PN 01 PKT-BUS 571 PASS
PN 01 PKT-BUS 572 PASS
PN 01 PKT-BUS 573 PASS
Command successfully completed
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...