Maintenance-Object Repair Procedures
555-233-143
8-306
Issue 1 May 2002
Example: This is WSP 1. An Aux Data of 201 indicates that WSP 2
probed this WSP, and it has a different address in the probe message than
WSP 1 has for WSP 2.
1. On WSP X, use the display atm wsp X command to determine its
address.
2. On this WSP, use the change atm wsp X command to change the
address of WSP X, if they do not match.
3. If the addresses do match, then the ATM switch has a different
address administered for WSP X, even though each WSP is
consistent.
System Technician-Demanded Tests:
Descriptions and Error Codes
There are no system technician-demanded tests associated with this MO.
Table 8-134.
Error type 1025 - Aux Data error codes for YY
YY
Meaning
1
The probing WSP (XX value in Aux Data) contains an ATM address in its
message that does not match the translation for that ATM address on this
WSP.
Summary of Contents for S8700 Series