MMI-PT
Issue 1 May 2002
8-1125
555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. The customer endpoint connected on a conference sent too many
messages to the VSP-MCU in a specified amount of time. Check the
“status conference” forms to correlate which customer had the problem.
This is a customer endpoint problem and not a VSP-MCU problem.
b. This port has been busied out by the busyout port UUCSSpp command.
c. Indicates that the circuit pack has been removed or has been insane for
more than 11 minutes. To clear the error, replace or reseat the circuit pack.
d. This error occurs if the MMI circuit pack detects a DSP Error. Maintenance
software will reset the DSP when this error is received. This error is logged
for all 8 resources connected to this particular DSP. If this DSP continues
to fail sanity, a Minor alarm is raised. Replace the circuit pack.
e. This error occurs when the Resource Loop-around test (#1111) fails. Run
the long test sequence, and note the results of Test #1111.
Table 8-463.
MMI-PT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
Any
Uplink error from pack
18 (b)
0
Busyout port PCSSpp
WARNING
OFF
release port UUCSSpp
130 (c)
Any
Software generated
WARNING
ON
257 (d)
Any
None
MAJOR
MINOR
ON
513 (e)
Any
Resource Loop-Back
test (#1111)
MINOR
ON
test port UUCSSpp sh r 3
1025 (f)
Any
Uplink error from pack
3841 –
3844 (g)
Any
Uplink error from pack
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...