display alarms
Issue 1 May 2002
7-89
555-233-143
To
Display alarm record to the time specified by mm/dd/hh/mm, where mm is
the month, dd is the day, hh is the hour and mm is the minute. If no “to”
date is entered, any alarm which is active after the from date will be
selected.
Equipment Type
The technician can choose between seven different equipment types. If
there is no input to any of these fields, the system will default to every type.
The user can select one of the following fields:
■
Cabinet: This allows the technician to display every alarm associated
with a particular cabinet. Alarms for a cabinet are referenced by a
number ranging from 1 to 3 which is assigned during cabinet
administration.
■
Port Network: This allows the technician to display every alarm
associated with a particular port network. Alarms for a port network
are referenced by a number ranging from 1 to 3.
■
Board Number: This allows the technician to display every alarm
associated with a particular circuit pack. Alarms for a
(cabinet-carrier-slot). If the cabinet number is omitted, the system will
default to 1.
■
Port: This allows the technician to display every alarm associated with
a particular port on a circuit pack. Alarms for a port circuit are
referenced by port location (cabinet-carrier-slot-circuit). If the cabinet
number is omitted, the system will default to 1.
■
Category: Alarms for a particular equipment category.
■
Extension: Alarms associated with an extension number.
■
Trunk (group/member): The technician can display every alarm
associated with a particular trunk group or trunk-group member. The
group identifier should be entered to view every alarm associated with
a trunk group
XXX/___. The group identifier and member identifier should both be
entered to view every alarm associated with a specific trunk-group
member XXX/XXX.
display alarms Page 1 of 1
ALARM REPORTS
The following options control which alarms will be displayed.
ALARM TYPES
Active? y_ Resolved? n_
Major? y_ Minor? y_ Warning? y_
REPORT PERIOD
Interval: m_ From: __/__/__:__ To: __/__/__:__
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet: ____
Port Network: __
Board Number: _______
Port: ________
Category: ________
Extension: _____
Trunk ( group/member ): ___/___
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...