Maintenance Commands
555-233-143
7-302
Issue 1 May 2002
Output
The following display shows a typical result when
status cabinet 1 is entered.
Field Descriptions
Carrier Location
The cabinet number and carrier letter of each carrier in the cabinet.
PN/SN Number
The Port Network number (1-22) or Switch Node number (1 or 2) of the
indicated carrier.
Carrier Type
The type of the indicated carrier: processor, port, expansion-control,
switch-node, dup-sw-node or not-used.
Cabinet Type
One of the following types:
MCC (multicarrier cabinet)
SCC (single-carrier cabinet)
S75XE (System 75 XE [pre-R1V4] single-carrier cabinet)
blank (undetermined cabinet type).
PN/SN
Each Port Network and Switch Node located in the cabinet is identified by
its PN number or its SN number and PNC designation (A or B).
status cabinet 1
CABINET CONFIGURATION STATUS CABINET CONNECTIVITY STATUS
Carrier PN/SN Carrier Cabinet PN/SN Connectivity Status
Location Number Type Type Active Standby
01A PN 1 processor MCC PN 1 up up
01B PN 1 processor SN 1 B-PNC up
01C PN 1 port SN 1 A-PNC up
01D SN 1 dup-sw-node
01E SN 1 switch-node
CABINET EMERGENCY TRANSFER CABINET ALARM STATUS
Emergency Select PN/SN Mj Mn Wn
Transfer Switch PN 1 0 2 1
01A off SN 1 B-PNC 0 0 0
01B off SN 1 A-PNC 0 0 0
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...