Maintenance-Object Repair Procedures
555-233-143
8-1748
Issue 1 May 2002
1324
FAIL
A non-service-affecting CSU module/Sync Splitter audit failure was detected by
the UDS1 circuit pack. No ports should be affected. No immediate action is
required. These errors indicate that the CSU module/Sync Splitter hardware
may have a problem, and that it should be replaced when practical to avoid
further deterioration.
1400
FAIL
Echo Canceller function failed. This could be a hardware problem on the
TN464GP/TN2464BP:
1. Issue the busyout board command.
2. Issue the reset board command.
3. Issue the test board long command.
4. Issue the release board command.
5. If Test 1420 still fails, replace the TN464GP/TN2464BP.
1401
FAIL
Echo Canceller memory failed, this could be a hardware problem on the
TN464GP/TN2464BP:
1. Issue the busyout board command.
2. Issue the reset board command.
3. Issue the test board long command.
4. Issue the release busy board command.
5. If the test still fails, replace the TN464GP/TN2464BP.
PASS
DS1 signal is present and the physical link is healthy. In addition, no Integrated
CSU/Sync Splitter errors or echo cancellation errors are detected.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board is shut down.
Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 8-673.
Test #138 Loss of Signal Alarm Inquiry Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...