BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Issue 1 May 2002
8-349
555-233-143
4
FAIL
For the TN2198 only:
Received a status of Level 1 Pending Activation, the NT1 has a loss of power
indicating a problem with the NT1.
1. For the NT1 follow the manufacturers recommended repair procedures.
2. Execute the test port PCSSpp command, and review the results of the
Level 1 Status Inquiry test to verify the repair. If the test is still failing
proceed to step 3.
3. Escalate the problem to the next tier.
PASS
This test indicates that Level 1 is activated, or that software has taken the port
out of service.
Table 8-147.
Test #621 Level 1 Status Inquiry —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page