TDM-CLK (TDM Bus Clock)
Issue 1 May 2002
8-1617
555-233-143
Board Type Check Test (#574)
This test verifies that a Tone-Clock circuit pack administered with a Stratum-3
clock source has code TN780.
Table 8-629.
Test #574 Board Type Check Test
Error
Code
Test
Result
Description / Recommendation
2012
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
ANY
FAIL
Stratum-3 clock synchronization is administered for the carrier where this
Tone-Clock circuit pack resides, but the Tone-Clock does not have code
TN780.
1. If the Stratum-3 clock option is incorrectly administered, remove it.
2. Otherwise, replace the circuit pack. See
Tone-Clock Circuit Pack’’ on page 8-1666
PASS
The proper Tone-Clock circuit pack code (TN780) is present for Stratum-3
clock synchronization.
Continued on next page