ANN-BD (Announcement Circuit Pack)
Issue 1 May 2002
8-133
555-233-143
2007
ABORT
The Announcement circuit pack thinks that Port 1 or Port 9 is busy.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, follow the Announcement port maintenance
procedures for Ports 1 and 9.
2100
ABORT
Could not allocate the necessary system resources to run this test.
ABORT
Internal system error. Retry the command at 1-minute intervals up to 5 times.
1–3
FAIL
Test failed. The error code indicates at which speech compression rate the test
actually failed (1 being the first rate tested, 3 being the last).
1. Reset the circuit pack using the reset board UUCSS command and then
run this test again. If the test continues to fail, replace the circuit pack.
2. If there are recurring alarms on this circuit pack caused by this test failing,
replace the circuit pack even if step 1 works.
!
CAUTION:
Replacing the circuit pack causes a loss of integrated announcements.
See
‘‘Essential Service Information’’ on page 8-120
of AN-LN-PT MO.
PASS
The record channel on the announcement circuit pack is functioning properly.
User-reported troubles on this circuit pack should be investigated using other
circuit pack and port tests. Refer to “ANN-PT” for a description of the port tests.
Table 8-49.
Test #210 140AY Loop-Around Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...