Maintenance-Object Repair Procedures
555-233-143
8-1250
Issue 1 May 2002
Error Log Entries and Test to Clear Values
Table 8-508.
Packet Interface Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Indicates that an alarm was raised but an associated error was not entered into the hardware error log due to a
momentary overload condition caused by a burst of hardware or software error reports. Run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended procedures.
0
Any
Any
ON
test packet-interface Uc l r 2
1 (a)
Any
None
MAJOR
ON
reset packet-interface Uc
2
2.
A Packet Interface circuit on an active IPSI can only be reset if it has been taken out of service by
background maintenance software. A Packet Interface circuit on a standby IPSI can be reset
independent of its service state.
10 (b)
0
None
50 (c)
0
None
257 (d)
Any
None
MAJOR
ON
reset packet-interface Uc
513 (e)
Any
None
MAJOR
ON
reset packet-interface Uc
769 (f)
Any
Maintenance
Loop-around test
(#886)
MAJOR
ON
test packet-interface Uc s r
2
1025 (g)
Any
Private Loop-around
test (#885)
MAJOR
ON
reset packet-interface Uc
1281 (h)
Any
None
MAJOR
ON
reset packet-interface Uc
1537 (i)
Any
Memory Checksum
test (884)
MINOR
ON
test packet-interface Uc l r 2
1793 (j)
Any
Memory Checksum
test (#884)
MINOR
ON
test packet-interface Uc l r 2
2049 (k)
Any
None
WARNING
ON
test packet-interface Uc r 25
2305 (l)
Any
None
test packet-interface Uc r 2
2561 (m)
Any
Active-Standby Peer
Link test (#888)
MINOR
OFF
test packet-interface Uc s r
2
2817 (n)
Any
Read and Clear test
(#887)
MINOR/
MAJOR
ON
test packet-interface Uc s
3074,
3073,
3072 (o)
Any
Maintenance
Loop-around test
(#886)
WARNING
OFF
test packet-interface Uc s r
2
3585 (p)
Any
None
WARNING
OFF
reset packet-interface Uc
3841 (q)
Any
None
MAJOR
OFF
reset packet-interface Uc
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...