status cabinet
This command lists the administered cabinets in the system.
Output
The following example shows the output for the
status cabinet command if the
value in the
Cabinet Layout
field on the Cabinet form is rack-mount-stack.
NOTE:
Since S8700 IP Connect configurations do not use PN maintenance boards,
the
Emergency Select Transfer Switch
field would equal NoEqp.
Table 7-46.
status cabinet command parameters
Action/ Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
status cabinet
init
inads
craft
none
none
status cabinet 1
CABINET CONFIGURATION STATUS CABINET CONNECTIVITY STATUS
Carrier PN/SN Carrier Cabinet PN/SN Connectivity Status
Location Number Type Type Active Standby
01A PN 1 rmc-port RMC PN 1 down
01B PN 1 rmc-port
01C PN 1 not-used
01D PN 1 not used
CABINET EMERGENCY TRANSFER CABINET ALARM STATUS
Emergency Select PN/SN Mj Mn Wn
Transfer Switch
PN 1 0 1 19
01B auto-
01A auto-
Command:
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...