RANL-STA (Remote Analog Line (Station) Port
Issue 1 May 2002
8-1333
555-233-143
RANL-STA (Remote Analog Line
(Station) Port
A per-port instance of this MO (RANL-STA) is used to maintain the circuitry
associated with a port which has been translated as analog station. The combo
blade circuit board has the capability of having two instances of this type of MO.
Failures of the neon message waiting lamp power and the common ringing
application circuitry are reported as part of common port circuit pack errors; see
errors 1281 and 1793 in
‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872
Ringing Caused by Maintenance Testing
Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing disturbs the customer or the terminal equipment,
disable it in the
Tests
field of the change station extension form. Be aware that
this action will also disable Test 35 on that station.
MO’s Name (in
Alarm Log)
Alarm Level
Initial SAT Command to
Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
pp is the 2-digit port number (01, 02,...).
Full Name of MO
RANL-STA
MINOR
test port UUCSSpp l
Remote Analog Line
Port
RANL-STA
WARNING
test port UUCSSpp sh
Remote Analog Line
Port
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...