status bri-port
Issue 1 May 2002
7-301
555-233-143
ASAI
BRI
0-126
Hyperactive
ignore
ignore
Link has sent too many messages
per unit time. Signaling has been
suspended. After 60 seconds, the
system attempts to put the link into
service. If a link remains in this state
while there is no activity at the BRI
endpoint, take the following steps:
1. Make sure SPID administration
on the switch and endpoints are
consistent. Repeat status
bri-port to determine whether
the Layer 2 state of the
signaling link is
L3-Established
. If it is
not, go to Step 2.
2. Try replacing the endpoint.
Repeat status bri-port to
determine whether the Layer 2
state of the signaling link is
L3-Established
. If it is
not, follow normal escalation
procedures.
ASAI
0-126
L3-Restarting
ext#
The switch has sent a Restart
message to the adjunct but has not
yet received a Restart
Acknowledgment message from the
adjunct.
ASAI
0-126
L3-Restarted
ext#
After receiving a Restart
Acknowledgment message, the
switch has sent a Heartbeat
message to the adjunct and is
waiting for a response.
ASAI
0-126
L3-Established
ext#
This is the normal state for ASAI
adjunct.
Table 7-45.
Interpreting BRI-Port Status Reports —
Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...