Maintenance-Object Repair Procedures
555-233-143
8-940
Issue 1 May 2002
MP Diagnostic Test (#1406)
This test is destructive.
The MP Diagnostic test (#1406) runs all of the diagnostic tests listed below, in the
order listed, but only if each successive test passes:
1. FPGA Query
2. TSI Query
3. ETHERNET Query
4. SCOTCH Sanity
FPGA Query
This test passes if the FPGA device on the TN2302 tests okay. Otherwise, it fails
with no fail code or AUX data.
This test verifies the status of the FPGA device on the TN2302 circuit pack. If the
device is bad, software sets an appropriate counter, posts an error and alarm, and
takes all DSPs out of service (all DSPs are controlled by the one FPGA).
Software then attempts to reset the FPGA. If the reset passes or the original test
passes, the DSPs are placed into service.
2805
FAIL
The number of pings received did not match the number sent (normally one
ping sent). This means that no ping responses were received from the
gateway defined on the ip-interfaces form for the Media processor.
1. Retry the command at 1-minute intervals up to 3 times.
2807
ABORT
The board is administered but not enabled in the change ip-interfaces form.
7, 89,
1007
FAIL
A ping to the destination failed through this port. This failure is because the
destination is down.
1. Verify that at least one destination is reachable through this port.
2. Once verified, execute the test port UUCSSpp command to verify that the
H.323 Signaling Group Ping test (#1387) passes.
PASS
Ping through this port is successful.
Table 8-365.
Test #1379 Ping Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...