![Avaya S8700 Series Maintenance Manual Download Page 780](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102780.webp)
Maintenance-Object Repair Procedures
555-233-143
8-58
Issue 1 May 2002
Station Present Test (or Ringing Application Test)
(#48)
This test applies momentary ringing voltage to the terminal equipment and
monitors resulting current flow to determine whether terminal equipment is
connected to the port. This test may cause some terminal equipment to ring
briefly during daily maintenance. If this ringing disturbs the customer or the
terminal equipment, you can disable it via the Tests field on the change station
form. However, on some software releases, Tests #6, 7, 161, and 35 are
disabled.
Table 8-24.
Test #48 Station Present Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station command to determine the service state of the
port. If the service state indicates that the port is active, wait until it is idle.
3. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1008
ABORT
Could not allocate a ringing circuit. Either every ringing circuit is active or the
ringing generator is either defective or incorrectly wired. Retry the command at
1-minute intervals up to 5 times.
1. If the test continues to abort, look for RING-GEN errors in the Error Log. If
an ABORT 1008 occurs for this test on other circuit packs as well, then the
ringing generator may be defective or is incorrectly wired. If it does not
occur on other ports, then all four ring phases are active.
1018
ABORT
The test has been disabled by administration. The default for the
Test?
field
on the station form is y. Determine why this field has been set to “n” on this
station (this may be due to the brief ringing disturbance that this test may
cause).
1. To enable the test for the particular analog station being tested, enter
change station extension and set the
Test?
field on the station to y.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...