CONFIG (System Configuration)
Issue 1 May 2002
8-477
555-233-143
The
Error Type
field specifies the carrier and slot location of the circuit pack
that caused the error as indicated in
. If the
Error Type
field is
greater than 1000, subtract 1000 from the
Error Type
field before consulting
the table.
Before proceeding, if multiple CONFIG errors are simultaneously logged with an
Aux Data of 1, investigate any EXP-INTF (Expansion Interface) errors.
Once the port’s circuit-pack location has been determined from
, use
the list configuration all command to determine whether the circuit pack is
inserted. If the circuit pack has already been inserted but the error persists,
replace the circuit pack. If not, insert the pack.
Converting Aux Data to Port-Network Number
Aux Data
Port-Network Number
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22