Maintenance-Object Repair Procedures
555-233-143
8-1840
Issue 1 May 2002
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 001: SCOTCH Synchronous Loop-Around test (#1275) failed.
1. Test the port (test port UUCSSpp long).
2. See
‘‘SCOTCH Synchronous Loop-Around Test (#1275)’’ on page
repair procedures.
b. Error Type 257: VAL port detected overrun or underrun condition that can
indicate a hardware problem.
1. Test for hardware problem (test port UUCSSpp long).
2. See
‘‘SCOTCH Synchronous Loop-Around Test (#1275)’’ on page
repair procedures to verify repair.
3. Clear the alarm (test port UUCSSpp long clear).
c. Error Type 3585: TDM Port Loop-Around test (#1285) failed.
1. Test the port (test port UUCsspp long).
2. See the
repair procedure.
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
There is no short test sequence for this MO. Every test is available in the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp l
1 (a)
0
SCOTCH Sync
Loop-Around test
(#1275)
MINOR
ON
test port UUCSSpp l r 3
257 (b)
0
WARNING
OFF
3585 (c)
0, 1
TDM Loop-Around
test (#1285)
MAJOR
ON
test port UUCSSpp l r 3
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...