ATM-SYNC (ATM Synchronization)
Issue 1 May 2002
8-267
555-233-143
ATM-SYNC Commands
Use the following commands to help troubleshoot ATM-SYNC problems:
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: problem with the primary DS1 reference. It is cleared when
the primary reference is restored. The following steps should give an
indication of the source of the problem:
change
synchronization
Allows primary and secondary references to be administered for
the Stratum 4 option, or
ATM-Switch
, indicating that the
synchronization references are input directly to the ATM switch
status
synchronization
Shows the current inferred synchronization reference
status
synchronization
Shows the administered primary and secondary
synchronization references
list timing-source
Displays all DS1 and UDS1 locations that are allowed to be
administered as primary or secondary references with the
change synchronization command
disable/enable
synchronization-
switch
Prevents or allows switching to another synchronization source
test
synchronization
Tests the administered synchronization source
Table 8-111.
Synchronization Error Log Entries
Error Type
Aux
Data
Associated
Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test synchronization
1 (a) (g)
None
WARNING/
MINOR
OFF
None
257 (b) (g)
None
WARNING/
MINOR
OFF
None
513 (c) (g)
None
WARNING/
MAJOR
OFF
None
1537 (d)
2
2.
It may take up to 1 hour for these alarms to clear via the “leaky bucket” strategy.
None
WARNING
OFF
None
1793 (e)
0-50
None
NONE
OFF
None
2049 (f)
0
None
WARNING
OFF
None
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...