DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 May 2002
8-565
555-233-143
The DS1 interface circuit pack detects a hardware error on the DS1 DIOD
trunk. The trunk cannot communicate with the far end because it is unable
to interpret digits sent from the far-end switch. Check with the far-end
switch or Operating Company for proper trunk connection.
k. Error Type 2305—Recorder message, trunk could not be seized (Aux
Data 50944). Run Test #314, and follow the outlined procedures.
l. Error Type 2562—Retry Failure error. This error is logged only. It is not a
hardware failure and hence does not start any testing or generate any
alarms. This error comes from Avaya MultiVantage ™ software and is
generated when a second attempt (retry) to seize an outgoing trunk fails.
m. Error Type 2817—Glare error. This error is logged only. It is not a
hardware failure and hence does not start any testing or generate any
alarms. This error is the result of a simultaneous seizure of a 2-way trunk
from both the near and far ends. Attempt to place the call again. If the
error persists, execute the Dial Tone Seizure test (#314), and follow those
procedures.
n. Error Type 3840—Port Audit and Update test (#36) failed due to an
internal system error. Enter the status trunk command to verify the status
of the trunk. If the trunk is out-of-service, then enter the release trunk
command to put it back into in-service. Retry the test command.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below. By
clearing error codes associated with the NPE Crosstalk test, for example, you
may also clear errors generated from other tests in the testing sequence.
Table 8-227.
System Technician-Demanded Tests: DS1-BD
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive, ND = Nondestructive
NPE Crosstalk test (#6)
X
ND
Conference Circuit test (#7)
X
ND
DS1 Dial Tone test (#314)
X
X
ND
Port Audit and Update test (#36)
X
X
ND
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...