ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 May 2002
8-285
555-233-143
System Technician-Demanded Tests:
Descriptions and error codes
Always investigate problems in the order presented. When you clear one of the
error codes associated with a given test, you clear errors generated by other tests
in the testing sequence. If you clear errors out of order, you can lose important
information.
Table 8-121.
System Technician-Demanded Tests: ATM-TRK
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset
Board
Sequence
D/ND
1
1.
D = Destructive, ND = Nondestructive
ATM Board Time Of Day Update (#1261)
X
ND
Connection Audit test (#50)
X
ND
Control Channel Loop test (#52)
X
ND
Packet Interface Loop Around test (#598)
X
X
ND
ATM DSP test (#1293)
X
X
ND
ATM Board Framer Looparound test
(#1260)
X
D
ATM Board Error Query test (#1259)
X
X
ND
ATM Cross Talk test (#1298)
X
ND
ATM Board Reset (#1256)
X
D
Continued on next page