![Avaya S8700 Series Maintenance Manual Download Page 882](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102882.webp)
Maintenance-Object Repair Procedures
555-233-143
8-160
Issue 1 May 2002
1141
ABORT
The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. Issue the test port long UUCSSpp command and review the results of the
BRI Port Local LAN Looparound test to verify the repair.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The loop-around test has failed.
1. If the test fails repeatedly, attempt to reset the circuit pack if the other ports
on the board are idle. Reset the circuit pack by issuing the busyout board
UUCSS and the reset board UUCSS commands.
2. If the test fails again, execute test pkt P on the management terminal. If
this fails, follow the failure procedures the in PKT-BUS section.
3. If the tests executed in step 2 pass, the problem is local to the BRI board.
Replace the circuit pack.
PASS
The BRI Port Local LAN Looparound test has passed.
Table 8-61.
Test #618 BRI Port Local LAN Looparound —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...