CO-TRK (Analog CO Trunk)
Issue 1 May 2002
8-469
555-233-143
1004
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1018
ABORT
The test was disabled via administration. Verify that the
Maintenance
Test
field on the Trunk Group form is set to ’n’. To enable the test, issue the
’change trunk-group x’ command (x equals the number of the trunk group to be
tested). Then, change the entry in the
Maintenance Test
field on the
form to ’y’.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7
FAIL
The conference capabilities of the port failed (Error Code 7).
129
The reflective 404-Hz Tone test failed. No transmission was detected to or
from the port (Error Code 129).
131
The reflective 1004-Hz Tone test failed. No transmission was detected to or
from the port (Error Code 131).
133
The reflective 2804-Hz Tone test failed. No transmission was detected to or
from the port (Error Code 133).
FAULT ISOLATION: Proceed as follows unless power or tone problems are
suspected (see notes on the next page).
1. To make sure the problem is on-board, disconnect the port from the CO
and retry the test. Coordinate this with the CO, or do it after busy hours;
otherwise, the CO may put the connection out of service.
2. If the retry fails, replace the circuit pack.
3. If the retry passes and no troubles have been reported, disable the test. If
the retry passes and troubles have been reported, refer the problem to the
CO.
Table 8-188.
Test #33 Looparound and Conference Circuit Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...