FIBER-LK (Fiber Link)
Issue 1 May 2002
8-851
555-233-143
136
FAIL
The Endpoint 1 SNI’s administered neighbor does not match the physical
neighbor connected. (The list fiber-link command displays a fiber link’s
endpoints.) The SNI’s assigned neighbor is another SNI, but the SNI is
physically connected to an EI. Enter list fiber-link, and verify that the
fiber-optic and metallic cables are installed as administered.
137
FAIL
The Endpoint 1 SNI’s administered neighbor does not match the physical
neighbor connected. (The list fiber-link command displays a fiber link’s
endpoints.) The SNI’s assigned neighbor is an EI, but the SNI is physically
connected to another SNI. Enter list fiber-link, and verify that the fiber-optic
and metallic cables are installed as administered.
138
FAIL
The physical location of SNI Endpoint 1’s neighbor does not match its
administered location. (Enter list fiber-link to display a fiber link’s endpoints.)
One location (carrier and slot) is assigned for the endpoint’s neighbor, but it
physically resides in another location.
1. Enter list fiber-link, and verify that the fiber-optic and metallic cables are
installed as administered.
2. If the problem does not seem to be caused by either a physical-connection
or an administration problem, replace the neighbor circuit pack. The
neighbor circuit pack may have a hardware problem causing it to report a
wrong angel address (physical carrier/slot address) to software.
139
FAIL
The Endpoint 1 SNI is administered to be connected to a DS1 CONV, but is not
physically connected to one. (The list fiber-link command displays a fiber
link’s endpoints.)
If a DS1 CONV should be connected to this SNI, enter list fiber-link, and verify
that the fiber-optic and/or metallic cables are installed as assigned.
If not, change administration to remove the DS1 converter complex from the
SNI’s fiber link by:
1. Entering list fiber-link to locate the fiber with this SNI as an endpoint
2. Entering remove fiber-link to remove the fiber
3. Entering add fiber-link to add the fiber back, without assigning the DS1
converter complex
Table 8-328.
Test #759 Configuration Audit —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...