Alarms, Errors, and Troubleshooting
555-233-143
4-34
Issue 1 May 2002
2. Enter status pnc at the S8700 Multi-Connect SAT. This display tells you
which TN230X board is active in a duplicated system and how many
alarms (if any) of each severity level have been logged for the board.
shows the output from this command.
Figure 4-10.
Screen output for status pnc command
3. Enter either list configuration UUC (for the carrier where the ATM-EI
packs reside) or display circuit-packs cabinet (non-control cabinet) at
the S8700 Multi-Connect SAT. This command tells you in more detail what
boards are in which slots in each cabinet and carrier. Verify that the
TN230Xs are physically located in the slots indicated on the display.
shows the output for the display circuit-packs 1
command.
shows the output for the display
circuit-packs 2 command.
status pnc
PORT-NETWORK CONNECTIVITY
Duplicated? no
Software Locked?
Standby Busied?
Standby Refreshed?
Interchange Disabled?
A-PNC B-PNC
Mode: active Mode:
State of Health: State of Health:
Inter PN Index: Inter PN Index:
Major Alarms: 0 Major Alarms:
Minor Alarms: 0 Minor Alarms:
Warning Alarms: 0 Warning Alarms:
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...