PPP-PT (Control LAN Packet/Port)
Issue 1 May 2002
8-1317
555-233-143
h. Error Type 2305-2816: System software detected a session is down. Aux
Data indicates the session number. These are log only errors. Error types
2305–2560 are for session numbers 1–256. Error types 2561–2816 are for
session numbers 257–512.
i. Error Type 3329: TCP/IP Ping test failed.
1. Test the port (test port UUCSSpp short).
2. See
‘‘TCP/IP Ping Test (#1281)’’ on page 8-1321
for repair
procedures.
j. Error Type 3585: TDM Port Loop-around test (#1285) failed.
1. Test the port (test port UUCsspp long).
2. See
‘‘TDM Loop-Around Test (#1285)’’ on page 8-1318
for repair
procedure.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate errors in the order they appear in the table below.
Table 8-528.
System Technician-Demanded Tests: PPP-PT
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive, ND = Nondestructive
TDM Loop-around test (#1285)
X
D
SCOTCH Synchronous Loop-around test (#1275)
X
D
TCP/IP Ping test (#1281)
X
X
ND
Session Status test (#1286)
X
X
ND
PPP Link Status test (#1279)
X
X
ND
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...