Maintenance-Object Repair Procedures
555-233-143
8-956
Issue 1 May 2002
AUX DATA Descriptions
y
Fault class/stimulus
causing software action
1
EAL fault class
2
PKT-INT fault class
3
TONE-BD fault class (not TDM-CLK)
4
TDM-CLK fault class (loss of clock)
7
Preference migration to A-side IPSI
z
Fault or improvement
0
This is an improvement in the previous fault class (y).
1
This is a degradation of the previous fault class (y).
Table 8-376.
Aux Data Descriptions for Software-Requested Interchange
Aux
Data
Description
0
No specific extra information is available
10
Interchange from B-side to A-side IPSI (possible preference switch)
20
Interchange from A-side to B-side IPSI
30
Control (archangel) moves from A-side IPSI to EI
40
Interchange from B-side to A-side IPSI, move archangel to EI
50
Interchange from A-side to B-side IPSI, move archangel to EI
60
No IPSI interchange, control (archangel) moves to A-side IPSI
70
No IPSI interchange, control (archangel) moves to B-side IPSI
80
Interchange from B-side to A-side IPSI, move archangel to IPSI
90
Interchange from A-side to B-side IPSI, move archangel to IPSI
100
Too faulted to take any action
110
Interchange from B-side to A-side IPSI, too faulted to move archangel to EI
120
Interchange from A-side to B-side IPSI, too faulted to move archangel to EI
Table 8-375.
Encoding of Error Codes for Software Requested IPSI interchange
Field
Variable Name
Value
Description
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...