Maintenance-Object Repair Procedures
555-233-143
8-1290
Issue 1 May 2002
The Inter-PN Index contains six fields (XX.XX.XX.XX.XX.XX), and the Inter-SN
Index has two (XX.XX). The Inter-PN Index reports faults in connectivity between
port networks and supersedes the Inter-SN Index, which reports faults in
connectivity between switch nodes. (The Inter-SN Index is only meaningful for
systems with a center stage switch having two switch nodes, each of which is
duplicated).
The meaning of each fault class field is given in the following table. A zero entry
indicates that there are no such faults reported. Higher numbers indicate
increasing number of faults. All zeros indicates perfect state of health. Unless the
PNCs are locked, the active PNC’s state of health should always be equal to or
better than the standby’s. (Otherwise, the system would perform a spontaneous
interchange.)
After a PNC-related alarm is cleared, the system performs a partial refresh of the
standby PNC. The corresponding fault class field is not updated to reflect the
improved state of health until the refresh is done. The state of health indexes will
not agree with the current alarm status during this period.
Inter SN Index: FC_SNIL s11.s10 FC_SNIHW
Table 8-521.
PNC State-of-Health Fault Classes
Fault Class
Priority
Description
MOs
FC_EAL
1
Number of PNs with EALs down
EXP-PN
FC_INL
2
Number of PNs with LINL, RINL, or
EI-SNI neighbor link faults
EXP-PN, SN-CONF
FC_BFD
1
1.
BFDLs only exist in Port networks that have an IPSI. Port networks that do not have an IPSI will
have the EI as Archangel and no BFDL faults.
3
Number of PNs with BFDL (Bearer
Fault Detection Link faults
SYS-LINK
FC_HW
4
Number of PNs affected by hardware
faults in a link having an EI as an
endpoint (Endpoints can be
determined with list fiber-link.)
EXP-INTF,
SN-CONF,
FIBER-LK, SNI-BD,
DS1C-BD
FC_PER
5
Number of PNs affected by SNI peer
link faults for SNIs connected to EIs
SNI-PEER
FC_DS1
6
Number of PNs affected by DS1C
facility faults
DS1FAC
FC_SNIL
7
Number of inter-switch-node fibers
affected by peer or neighbor link
faults
SNI-PEER
FC_SNIHW
8
Number of interswitch-node fibers
affected by hardware faults
SN-CONF, SNI-BD,
FIBER-LK
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...