set tone-clock
Issue 1 May 2002
7-289
555-233-143
set tone-clock
set tone-clock UUC [override]
This command forces a Tone-Clock interchange for a non-IPSI controlled port
network. If the port network has an IPSI for a Tone-Clock, this command is
blocked.
On port networks with duplicated Tone-Clocks, this command is used to select
which of the two Tone-Clock circuit packs is to be active.
In PNs, the A-carrier Tone-Clock is the preferred Tone-Clock. It is always active
unless a failure, maintenance testing, or use of this set command has caused an
interchange to the B-carrier Tone-Clock. If you have used this command during a
maintenance session, set the PN Tone-Clock back to the A carrier when you are
finished, assuming it is healthy. Tone-clock interchanges executed by scheduled
daily maintenance cause the standby to become active for 20 seconds and then
interchange back to whichever Tone-Clock was originally active.
Cabinet number defaults to 1.
Parameters
Examples
set tone-clock 01c override
set tone-clock a
override
This qualifier forces execution of the set command regardless of the health of the
Tone-Clock circuit pack.
!
CAUTION:
Use of this option is destructive to an entire port network for PNs.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...