MEDPRO (Media Processor MAPD Circuit Pack)
Issue 1 May 2002
8-1077
555-233-143
Ping Test (#1379)
This test is nondestructive
This test verifies that the MedPro circuit pack can communicate to other nodes on
the LAN.
This test pings the gateway IP address as defined on the IP Interface form.
If the PING is successful, this test looks at the PING round trip delay. If a round
trip delay of greater than 4 seconds is reported, a separate error is logged.
Excessive round trip delays do not take the MedPro out of service.
Services can execute the standard PING command using the C-LAN board
address and MedPro IP address to see the actual round-trip delay. (See ping
commands).
This test is a nondestructive test. It runs because of in-line errors, during periodic
and schedule maintenance, and on demand.
Table 8-439.
Test #1379 Ping Test
Error
Code
Test
Result
Description / Recommendation
1, 2
ABORT
Internal Error.
1. Retry the command at 1-minute intervals up to 3 times.
7
ABORT
Destination unreachable.
1. Verify that at least one destination reachable through this port is up.
2. Repeat the test.
3. If the test still aborts, escalate the problem.
2000
ABORT
Response to the test was not received from the Media Processor circuit pack
within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack. Reset
the circuit pack by issuing the busyout board UUCSS and the reset
board UUCSS commands.
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABORT
The necessary system resources to execute the test could not be allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...