test ds1-facility
test ds1-facility UUCSSf [short | long | external loopback] [repeat#]
[schedule]
The test ds1-facility command performs a series of tests on the specified facility.
Each individual test will exercise diagnostics on the facility and then return results
of the test along with any possible error codes. The long test is destructive and is
not allowed unless the facility has been busied out.
Parameters
Examples
test ds1-facility 04a01d
test ds1-facility 03a01a sh c
UUCSSf
A DS1 facility is specified by the location of the DS1 Converter circuit pack and a
letter from a to d corresponding to the four facilities connected to the circuit pack.
external
loopback
This specifies a destructive test that sends a test pattern to an external device and
returns it for comparison to the original. Configure the external device to loop back
the signal. See
‘‘DS1-FAC (DS1 Facility)’’ on page 8-659