![Avaya S8700 Series Maintenance Manual Download Page 1119](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021119.webp)
CARR-POW (Carrier Power Supply)
Issue 1 May 2002
8-397
555-233-143
shows AC power distribution in some multicarrier cabinets. The DC
power-distribution cables are on both sides of the cabinet. These cables supply
power to each of the carriers. The optional battery charger is at the right side of
the power-distribution unit.
Figure 8-17.
AC Power Distribution in Multicarrier Cabinets
Power Backup
If AC power fails, three 48-V DC batteries power the system for:
■
15 seconds in an EPN cabinet
■
10 minutes in the expansion control carrier in the “A” position of an EPN
cabinet
3
2
"C" Position
Carrier
"B" Position
Carrier
"A" Position
Carrier
"D" Position
Carrier
Battery
Charger
(Optional)
"E" Position
Carrier
"F" Position
Fan Unit
Power
Distribution
Unit
mcc4_g3 RBP 041696