IPMEDPRO (IP Media Processor Circuit Pack)
Issue 1 May 2002
8-937
555-233-143
IP Address Query Test #1371
This test is destructive.
This test sends the Media processor the IP address, subnet mask, and gateway
translation (IP parameters). If the parameters do not match software translation,
the maintenance sub-system reboots the board. The board goes through a
physical board removal and insertion.
When this test fails, it is an indication that an illegal change was made and the
customer should be notified.
Table 8-363.
Test #1371 IP Address Query Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Insufficient system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2801
ABORT
Unable to find IP address data for this location. Verify that the board is
administered.
2807
ABORT
The board is administered, but not enabled in the change ip-interfaces form.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...