Maintenance-Object Repair Procedures
555-233-143
8-894
Issue 1 May 2002
If the PING is successful, this test looks at the PING round-trip delay. If a
round-trip delay of greater than 4 seconds is reported, a separate error is logged.
Excessive round-trip delays within the signaling group will not take the signaling
group out of service, however.
Services can execute the standard PING command using the C-LAN board’s
address and far-end IP address from the signaling group form to see the actual
round-trip delay.
This test checks the circuitry involved in the data path of a peer-to-peer IP layer
connection.
This test is a nondestructive test. It runs because of in-line errors, during periodic
and scheduled maintenance, and on-demand.
Table 8-342.
Test #1387 H.323 Signaling Group Ping Test
Error
Code
Test
Result
Description / Recommendation
1, 2
ABORT
Internal Error.
1. Retry the command at 1-minute intervals up to 3 times.
7
ABORT
Destination unreachable.
1. Verify that the C-LAN has been administered with an IP-Route that enables
the C-LAN to reach the far-end IP address.
2. Once verified, execute test sig-group grp# command to verify that the
H.323 Signaling Group Ping test (#1387) passes.
1005
ABORT
Configuration for this test is incorrect.
1. Verity that the link is in service with the status port or status link
command. Verify that the routing table has destinations that are reachable
through this port.
2. Repeat the test.
3. If the test aborts with Error Code 7, while step 1 verified, escalate the
problem.
1125
ABORT
Link is not in service.
1. Check if the link is in service or not. If the link is not in service, release the
link using release link or release port command and repeat the test. This
is a normal abort.
2. If the test continues to abort after following the repair procedures, escalate
the problem.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...