Maintenance-Object Repair Procedures
555-233-143
8-1280
Issue 1 May 2002
It should be noted that when restoring the PMS printer link, it is necessary to
execute tests on different MOs that comprise the link; it is recommended that you
busyout the PMS printer link before trying to restore the link. If the PMS printer
Link is busied out, then every PMS printer Link maintenance action is deactivated,
and interference with tests of other MOs is prevented.
Error Log Entries and Test to Clear Values
Notes:
a. Craft busied out the Journal Printer Link. The link is torn down. Enter
release journal wakeup-log | pms-log command to restore the link.
b. Link Retry test (#215) fails. Physical link cannot be set up, usually because
of hardware problems such as power off or cable disconnect. See
‘‘Procedures for Restoring the PMS Printer Link’’ on page 8-1279
c. Physical link cannot be set up, usually because of hardware problems such
as power off or cable disconnect. The PMS Printer Link physical link is
down due to the following causes: cable to the printer device is
disconnected, the printer device is powered off, or the data extension
where the printer device connects to has been busied out. Check the
connectivity of wire and cable among wall jacket, data module, and the
printer device. Enter status data extension and verify that the data
extension of the printer device is in the in-service/idle state. If the data
extension is not available, then see
‘‘Procedures for Restoring the PMS
Table 8-518.
PMS-PRNT/JNL-PRNT Link Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures. Both PMS Printer and Journal Printer are
administered to the same extension, and the printer is not connected. Refer to the Procedures for Restoring the
PMS Printer Link above for resolution.
0
Any
Any
Any
test journal wakeup-log |
pms-log sh
18 (a)
0
busyout journal
wakeup-log | pms-log
WARNING
OFF
release journal
wakeup-log | pms-log
257 (b)
Any
Link Retry test(#215)
MINOR
2
WARNING
2.
Minor alarms may be downgraded to Warning alarms based on the value used in the set options command.
OFF
test journal wakeup-log |
pms-log long
513 (c)
Any
test journal wakeup-log |
pms-log
769 (d)
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...