Maintenance-Object Repair Procedures
555-233-143
8-534
Issue 1 May 2002
Signaling Path PING Test (#1373)
This test is nondestructive.
The test determines the local C-LAN through which the signaling originates and
the endpoint’s IP address. It then requests the local C-LAN to execute a PING on
the endpoint’s address. If the PING is successful, the test passes, if the PING is
not successful, the test fails.
NOTE:
Multiple failures of this test can take the Digital IP Station out of service.
This test checks the circuitry involved in the data path of a peer-to-peer IP
layer connection.
NOTE:
This nondestructive test runs due to in-line errors, during periodic and
schedule maintenance, and on demand.
Table 8-214.
Test #1372 Registration Status Inquiry
Error
Code
Test
Result
Description / Recommendation
1, 2, 3
FAIL
The endpoint is not successfully registered.
1. Verify that the user is entering:
■
the correct extension and security code
■
the C-LAN IP address
2. Verify that the extension has been enabled for IP softphone operation.
3. If many endpoints cannot register, investigate any errors of the C-LAN’s
Ethernet port.
4. Examine the Ethernet cabling from the endpoint PC to the Ethernet hub.
PASS
The endpoint is successfully registered and continues to respond to registration
handshaking.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...